Processing Excellence
Each donor is processed as a single lot and all the processing steps are performed aseptically in clean rooms. The steps include:
- Initial debridement and precision milling/cutting using sophisticated CNC machines
- Patented and validated process of disinfection: several cycles of soaking in mild chemical solutions and washing designed to inactivate any pathogens and remove immunogenic material
- Demineralization where applicable
- Lyophilization/freeze drying
- Final sterility testing by microbial culture method/gamma irradiation